Summary for Test 2019-12-04-6-3
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
---|---|
DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
Award Date | 04/19/2019 |
Closeout Date | 05/28/2024 |
Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 12/04/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | 7/8"x10.5" F1554 Gr55 |
The quantity of what the sample constitutes | 33 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-412-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 1201002353 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 Gr55 |
Bolt Length(s) | 10.5" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 47299-PPO |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2019-12-04-6
DIME Test ID: 2019-12-04-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-12-11
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 12/10/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 1201002353
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW
Size: .875 in
Bolt Length: 10.5 in
Measurement Average: 5.93 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/11/2019 ✔