Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-12-04-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213749
DEA: 120C1104
EFIS: 1200000633
DIST-CO-RTE-PM12-ORA-57-20.3/21.6
Award Date04/19/2019
Closeout Date05/28/2024
Work DescriptionSR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING
QA Service Level1 (Verified on 05/31/2019)

Sample Information

Sample Taken Date12/04/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2019
Sample typeQuality Assurance A brief description of the sample7/8"x10.5" F1554 Gr55
The quantity of what the sample constitutes33 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-412-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)1201002353 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationF1554 Gr55
Bolt Length(s)10.5" Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot Number47299-PPO
Rocap Test Requirement(s)No Lubricant Requirements(s)No

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-12-04-6-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/10/2019spaine
Yes
12/11/2019F1554 Tensile
2019-12-04-6-2ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory12/10/2019Fred Saylor
Yes
12/11/2019
2019-12-04-6-3ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory12/10/2019Fred Saylor
Yes
12/11/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-12-04-6-1 ASTM F606-14 (Verified)
DIME Test ID: 2019-12-04-6-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-12-04-6-3 ASTM B499-14 (Verified)