Summary for Test 2019-12-04-6-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
---|---|
DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
Award Date | 04/19/2019 |
Closeout Date | 05/28/2024 |
Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 12/04/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | 7/8"x10.5" F1554 Gr55 |
The quantity of what the sample constitutes | 33 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-412-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 1201002353 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 Gr55 |
Bolt Length(s) | 10.5" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 47299-PPO |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2019-12-04-6
DIME Test ID: 2019-12-04-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-12-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/10/2019
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | UNC 7/8 | 0.462 | 39976 | 177 | 86515 | 67233 | 31062 | F1554 Tensile |
General comments (publicly viewable) (Max 1000 characters): F1554 Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 12/11/2019 ✔