Summary for Test 2018-12-21-1-71
Test performed: ASTM E18-15Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/21/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/26/2018 |
Sample type | Verification | A brief description of the sample | 2", 2 1/4', 2 1/2" A563-DH HDG and plain nuts |
The quantity of what the sample constitutes | 3 and 5 ea | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-256-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
---|---|---|---|
Heat Number(s) | 188527, 177682, 188194, 188739, 188360, 156042, 188360, 188451 | Nut Mfg. Lot Number(s) | Dyson- DDZP, DDYC, DDYO, DEAC, DDZA, DDTN, DDZD, DDZR |
Washer Mfg. Lot Number(s) | n/a | Bolt Specification | n/a |
Bolt Length(s) | n/a | Nut Specification | A563-DH |
Washer Specification | n/a | Finish | HDG and plain |
Diameter/Size | 2", 2 1/4", 2 1/2" | Bolt Mfg. Lot Number | n/a |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2018-12-21-1
DIME Test ID: 2018-12-21-1-71
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2019-01-15
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 01/04/2019
Sample No.: 6A
Rocap Number: no data
Heat Number(s): 156042
Mfg. Lot Number: DDTN
Finish Coating: Plain
Product Markings: TDC DH 2H
Size: 2.5 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 28.25
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/8/2019 ✔