Summary for Test 2018-05-14-10-9
Test performed: CTM 670-December 2013Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/14/2018 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2018 |
Sample type | Department Acceptance | A brief description of the sample | End Anchors |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anirudha | Last name of sampler or witnessed by | Vaidya |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Erico Nucor, Cascade | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Rebar Heat Number(s) | 283716, SE16104115, SE1610357301, SE16103928 | Head Manufacturer Lot Number(s) | LA-870, 872, 884, 835 |
Rebar Size | 4, 6, 7, 8 | Headed Bar Model Name | DR14 |
Size of Head | Full Size - 9x | Head Connection Type | Inertia Weld |
Head Shape | Circular | Rebar Manufacturer | Cascade Nucor |
Head Manufacturer | Erico | Head Fabricator | Erico Lention |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2018-05-14-10
DIME Test ID: 2018-05-14-10-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-05-28
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/16/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Cycle-1 | 100 | #7/22mm | End Anchor LA-884 | 0.6 | 59630 | 99383 | NECKING OK | Fred |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 5/21/2018 ✔