Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-05-14-10

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2018
Sample typeDepartment Acceptance A brief description of the sampleEnd Anchors
The quantity of what the sample constitutes16 From where was the sample collectedManufacturer
First name of sampler or witnessed byAnirudha Last name of sampler or witnessed byVaidya
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameErico Nucor, Cascade Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)283716, SE16104115, SE1610357301, SE16103928 Head Manufacturer Lot Number(s)LA-870, 872, 884, 835
Rebar Size4, 6, 7, 8 Headed Bar Model NameDR14
Size of HeadFull Size - 9x Head Connection TypeInertia Weld
Head ShapeCircular Rebar ManufacturerCascade Nucor
Head ManufacturerErico Head FabricatorErico Lention
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-05-14-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/28/2018NECKING OK
2018-05-14-10-10CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/17/2018Fred
Yes
05/28/2018NECKING OK

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-05-14-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-12 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-13 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-14 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-15 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-10-16 CTM 670-December 2013 (Verified)