Summary for Test 2016-09-07-1-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 09/07/2016 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/09/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | HUNG | Last name of sampler or witnessed by | NGO |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 889-09F | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NATIONAL READY MIX | Transportation Laboratory (TL) Number | 2016-09F |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | RW 1613 |
Structure name | BURBANK WESTERN CHANNEL PRECAST PRESTESSED DECK PANELS GROUP 12 |
Material Information
Material Type | Concrete | The concrete mix design number | S72035 |
---|---|---|---|
The truck number from where the sample was collected | 394 | The batch plant ticket number from where the sample was collected | 201026 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | BURBANK WESTERN CHANNEL PRECAST PRESTESSED DECK PANELS GROUP 12 |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-09-07-1
DIME Test ID: 2016-09-07-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-09-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 09/09/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 74760 lb
Maximum load on cylinder 2: 71760 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 0.00
Age of specimen: 2 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 2,626.8 psi
Compressive strength of cylinder 2: 2,521.4 psi
Compressive strength (to nearest 10 psi): 2570 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2016 ✔