Summary for Test 2019-11-15-20-5

Test performed: AASHTO T269-14

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/15/2019 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing11/15/2019 Sample typeVerification
A brief description of the samplePlant Produced 1/2-inch Type A HMA (eq. PG 64-10) The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byAdam
Last name of sampler or witnessed byZeither Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Pleasanton
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2019-11-15-20
DIME Test ID: 2019-11-15-20-5
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-11-17

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 11/15/2019
123

3.2 %

3.4 %

3.4 %

3.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/17/2019 ✔