Summary for Test 2017-12-14-1-31
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 211889 DEA: 08368514 EFIS: 0813000077 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-81.1/87.5&177.3/181.1 |
Award Date | 05/02/2017 |
Closeout Date | 12/09/2019 |
Work Description | CONSTRUCT AIF AND DEMOLISH EXISTING AIF IN YERMO |
Location Description | SAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF YERMO ROAD OVERCROSSING TO 1.0 MILE SOUTH OF MINNEOLA ROAD OVERCROSSING AND FROM 1.2 MILE NORTH OF NIPTON ROAD OVERCROSSING TO 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 04/07/2017) |
Sample Information
Sample Taken Date | 12/14/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/14/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolt Assemblies |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Source |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
Title of sampler | QA Inspector | Telephone number of sampler | 6616185971 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | 2017-12-14-1 |
The fabricator/manufacturer/facility name | K and J Steel | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-289-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 100884905, 10088218, NF14102181, 100785838, 10391980, 10498480, 10433230, 10286370 | Nut Mfg. Lot Number(s) | 20932-M58090, 26503-75065969, 24083-75063411, 17154-62130915, 391703A, 382494B, 344208B, 387411A |
Washer Mfg. Lot Number(s) | 031357, 028700, 030986, 031793, C9744, D3960 , D3161, 7250M, | Bolt Specification | F3125 / F1852 |
Bolt Length(s) | 1-3/4", 2", 2-1/4", 2-1/2" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | Mechanically Galvanized |
Diameter/Size | 5/8, 3/4 | Bolt Mfg. Lot Number | 21576-10391980, 29403-10498480, 25113-1043323 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-12-14-1
DIME Test ID: 2017-12-14-1-31
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-01-11
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 01/02/2018
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 388399A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 TC N
Size: .75 in
Bolt Length: 1.75 in
Measurement Average: 2.36 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/4/2018 ✔