Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2017-12-14-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211889
DEA: 08368514
EFIS: 0813000077
DIST-CO-RTE-PM08-SBD-15-81.1/87.5&177.3/181.1
Award Date05/02/2017
Closeout Date12/09/2019
Work DescriptionCONSTRUCT AIF AND DEMOLISH EXISTING AIF IN YERMO
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF YERMO ROAD OVERCROSSING TO 1.0 MILE SOUTH OF MINNEOLA ROAD OVERCROSSING AND FROM 1.2 MILE NORTH OF NIPTON ROAD OVERCROSSING TO 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING
QA Service Level1 (Verified on 04/07/2017)

Sample Information

Sample Taken Date12/14/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/14/2017
Sample typeQuality Assurance A brief description of the sampleA325 Bolt Assemblies
The quantity of what the sample constitutes8 From where was the sample collectedSource
First name of sampler or witnessed byTory Last name of sampler or witnessed byMcLaurin
Title of samplerQA Inspector Telephone number of sampler6616185971
Laboratory sample identificationUnknown Linked DIME Sample ID2017-12-14-1
The fabricator/manufacturer/facility nameK and J Steel Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL67-289-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100884905, 10088218, NF14102181, 100785838, 10391980, 10498480, 10433230, 10286370 Nut Mfg. Lot Number(s)20932-M58090, 26503-75065969, 24083-75063411, 17154-62130915, 391703A, 382494B, 344208B, 387411A
Washer Mfg. Lot Number(s)031357, 028700, 030986, 031793, C9744, D3960 , D3161, 7250M, Bolt SpecificationF3125 / F1852
Bolt Length(s)1-3/4", 2", 2-1/4", 2-1/2" Nut SpecificationA563 DH
Washer SpecificationF436 FinishMechanically Galvanized
Diameter/Size5/8, 3/4 Bolt Mfg. Lot Number21576-10391980, 29403-10498480, 25113-1043323
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-12-14-1-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018A325 TC
2017-12-14-1-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018A325 TC
2017-12-14-1-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-4ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-5ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-6ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-7ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-8ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-9ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load
2017-12-14-1-10ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/22/2017Brian
Yes
01/11/2018Nut Proof Load