Summary for Test 2024-04-29-30-5

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994588
DEA: 081H3904
EFIS: 0817000032
DIST-CO-RTE-PM08-SBD-15-R20.5/R21.6,R25.5/R30.7
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date04/29/2024 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2024
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.75% LAS
The quantity of what the sample constitutes4 Bags Of Bin Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byG Last name of sampler or witnessed byRamirez
Title of sampler Telephone number of sampler
Laboratory sample identification0206A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Oro Grande Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0022, 91-36-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Oro Grande Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number224112A ORO SJR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-29-30
DIME Test ID: 2024-04-29-30-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-06-12

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 05/02/2024
Clay Level (Test 1): 5.1
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.2
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5.1
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 77
Sand Equivalent (Test 2): 75
Sand Equivalent (Test 3): 79
Sand Equivalent: 77
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/12/2024