Summary for Test 2023-09-25-6-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993118
DEA: 101C3304
EFIS: 1014000146
DIST-CO-RTE-PM10-SJ-205-R4.6/R9.0
Award Date04/05/2022
Closeout DateNot set
Work DescriptionWidening bridges, ramps and roadway. SR205 SMART CORRIDOR - PHASE 2
Location DescriptionOn state highway in San Joaquin County in and near Tracy from Janney Overhead to 1.3 miles east of MacArthur Drive Overcrossing.
QA Service Level1 (Verified on 07/06/2022)

Sample Information

Sample Taken Date09/25/2023 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing09/27/2023 Sample typeQuality Assurance
A brief description of the sample#6 2'-8" The quantity of what the sample constitutes8376 pieces
From where was the sample collectedFabricator First name of sampler or witnessed byLorenzo
Last name of sampler or witnessed byGarcia Title of sampler
Telephone number of sampler17029172503 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL115-091-22
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4130418
Hoop Manufacturer Lot Number(s)Lots 1, 4 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Rebar San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-09-25-6
DIME Test ID: 2023-09-25-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-09-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 09/28/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1216/19mm0.4440548.5192156Ultimate - Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ultimate - Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/28/2023 ✔