Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2023-09-25-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993118
DEA: 101C3304
EFIS: 1014000146
DIST-CO-RTE-PM10-SJ-205-R4.6/R9.0
Award Date04/05/2022
Closeout DateNot set
Work DescriptionWidening bridges, ramps and roadway. SR205 SMART CORRIDOR - PHASE 2
Location DescriptionOn state highway in San Joaquin County in and near Tracy from Janney Overhead to 1.3 miles east of MacArthur Drive Overcrossing.
QA Service Level1 (Verified on 07/06/2022)

Sample Information

Sample Taken Date09/25/2023 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/27/2023
Sample typeQuality Assurance A brief description of the sample#6 2'-8"
The quantity of what the sample constitutes8376 pieces From where was the sample collectedFabricator
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of sampler Telephone number of sampler17029172503
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-091-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4130418
Hoop Manufacturer Lot Number(s)Lots 1, 4 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Rebar San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-09-25-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking
2023-09-25-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking
2023-09-25-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking
2023-09-25-6-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking
2023-09-25-6-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking
2023-09-25-6-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2023aauvinen
Yes
09/28/2023Ultimate - Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-09-25-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-25-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-25-6-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-25-6-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-25-6-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-25-6-6 CTM 670-December 2013 (Verified)