Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2016-09-19-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date09/19/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/21/2016
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byJOSE Last name of sampler or witnessed byDIAZ
Title of samplerTET Telephone number of samplerUnknown
Laboratory sample identification888-SRL313 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHolliday Rock UPLAND Transportation Laboratory (TL) NumberSRL-313
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier91 CIP
Structure name91 CIP

Material Information

Material TypeConcrete The concrete mix design numberCM5640
The truck number from where the sample was collected160 The batch plant ticket number from where the sample was collected101085803
Concrete batch plantNP The fabricator/manufacturer designation for the samplePLANT
A detailed description of where the material sample was collectedLOAD 1 Where the material sample would have been placed if not sampledBR 18 BENT 2 MAIN ST UC
From Lot No.NP Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-09-19-11-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory10/17/2016Matthew Clayton
Yes
10/17/2016

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-19-11-1 ASTM C39-17a (Verified)