Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2024-04-29-33

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994588
DEA: 081H3904
EFIS: 0817000032
DIST-CO-RTE-PM08-SBD-15-R20.5/R21.6,R25.5/R30.7
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date04/29/2024 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2024
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byRamirez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Oro Grande Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-04-29-33-1AASHTO T228-22: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)Anthony Hernandez, CT D08 - Fontana Southern Regional Laboratory05/02/2024Anthony Hernandez
Yes
05/08/2024
2024-04-29-33-2AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)Sm Ali, CT D08 - Fontana Southern Regional Laboratory05/02/2024Sm Ali
Yes
05/08/2024- 0.068 + 0.006 = - 0.062
2024-04-29-33-3AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory05/02/2024Sunday Agude
Yes
05/08/2024
2024-04-29-33-4AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory05/02/2024Sunday Agude
Yes
05/08/2024
2024-04-29-33-5AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational ViscometerSunday Agude, CT D08 - Fontana Southern Regional Laboratory05/02/2024Sunday Agude
Yes
05/08/2024
2024-04-29-33-6AASHTO T44-18: Standard Method of Test for Solubility of Bituminous MaterialsAnthony Hernandez, CT D08 - Fontana Southern Regional Laboratory05/02/2024Anthony Hernandez
Yes
05/08/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-29-33-1 AASHTO T228-22 (Verified)
DIME Test ID: 2024-04-29-33-2 AASHTO T240-17 (Verified)
DIME Test ID: 2024-04-29-33-3 AASHTO T315-12 (Verified)
DIME Test ID: 2024-04-29-33-4 AASHTO T315-16 (Verified)
DIME Test ID: 2024-04-29-33-5 AASHTO T316-17 (Verified)
DIME Test ID: 2024-04-29-33-6 AASHTO T44-18 (Verified)