Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2024-01-11-57

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/11/2024
Sample typeAnnual Source Testing A brief description of the sampleType II/V Portland Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM245418 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSRMG Clarkdale II/V Cement Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandSalt River Materials Group
MillClarkdale Type of Cementitious MaterialType II/V Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-01-11-57-1ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement MortarAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory07/18/2024Benjamin Lenz
Yes
09/12/2024
2024-01-11-57-2ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat NeedleAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory06/26/2024Benjamin Lenz
Yes
09/12/2024
2024-01-11-57-3ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatusk, CT HQ - Sacramento Cement Testing Laboratory06/10/2024Benjamin Lenz
Yes
09/12/2024
2024-01-11-57-4ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory06/26/2024Benjamin Lenz
Yes
09/12/2024
2024-01-11-57-5ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)KH, CT HQ - Sacramento Cement Testing Laboratory09/12/2024
Yes
09/12/20243 day
2024-01-11-57-6ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)KH, CT HQ - Sacramento Cement Testing Laboratory09/12/2024
Yes
09/12/2024Specimen 3 was eliminated from the average for being outside allowable limits per ASTM C109
2024-01-11-57-7ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)KH, CT HQ - Sacramento Cement Testing Laboratory09/12/2024
Yes
09/12/2024Specimen 1 was eliminated from the average for being outside allowable limits per ASTM C109

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-01-11-57-1 ASTM C185-15a (Verified)
DIME Test ID: 2024-01-11-57-2 ASTM C191-13 (Verified)
DIME Test ID: 2024-01-11-57-3 ASTM C204-11 (Verified)
DIME Test ID: 2024-01-11-57-4 ASTM C187-16 (Verified)
DIME Test ID: 2024-01-11-57-5 ASTM C109-21 (Verified)
DIME Test ID: 2024-01-11-57-6 ASTM C109-21 (Verified)
DIME Test ID: 2024-01-11-57-7 ASTM C109-21 (Verified)