Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-07-21-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210040
DEA: 04297624
EFIS: 0400020581
COOP: 042558
DIST-CO-RTE-PM04-ALA-84-22.9/25.7
Award Date09/30/2015
Closeout Date03/12/2020
Work DescriptionWIDENING AND EXPRESSWAY UPGRADES
Location DescriptionON ROUTE 84, FROM RUBY HILL DRIVE TO NORTH OF CONCANNON BOULEVARD
QA Service Level1 (Verified on 11/10/2015)

Sample Information

Sample Taken Date07/21/2016 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2016
Sample typeQuality Assurance A brief description of the sampleBartec Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byOscar Last name of sampler or witnessed bySantos
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDextra America Nucor Transportation Laboratory (TL) NumberC714506
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size#11 Coupler ModelBartec
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)DL14101108 Rebar Heat Number(s)SE15104089
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-07-21-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2016Fred
Yes
07/26/2016OK Necking
2016-07-21-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2016Fred
Yes
07/26/2016OK Necking
2016-07-21-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2016Fred
Yes
07/26/2016OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-21-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-21-6-2 CTM 670-December 2013 (Verified)