Sample Record

Owner Labs

  • CT D05 - Monterey Construction Field Laboratory
  • CT D05 - Santa Cruz Field Laboratory

DIME Sample ID 2023-02-17-16

Project Information

Project IdentifiersProject ID: 994486
DEA: 051Q0804
EFIS: 0522000148
DIST-CO-RTE-PM05-SCR,SCR/SCR-9,1-17.41/17.5
Award DateNot set
Closeout DateNot set
Work DescriptionRepair of viaduct barrier wall and replace CIDH piles. Holiday Lane Viaduct Slipout. State Route 9 at PM SCR-09-8.4 Jay's Slide, and SR 236 (SCR-236-16.87)
Location DescriptionSanta Cruz County. State Route 9 at PM SCR-09-8.4 and SR 236 (SCR-236-16.87)
QA Service Level1 (Verified on 02/13/2023)

Sample Information

Sample Taken Date02/17/2023 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/21/2023
Sample typeQuality Assurance A brief description of the sampleCIDH Wet Hole PCC
The quantity of what the sample constitutes10 Cy From where was the sample collectedJob Site
First name of sampler or witnessed byJoseph Last name of sampler or witnessed byEsteybar
Title of samplerASR Telephone number of sampler2094708827
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLas Animas Concrete Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number713W25S
The truck number from where the sample was collected111 The batch plant ticket number from where the sample was collected366216
Concrete batch plantLas Animas Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete sample from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-02-17-16-3ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteJoseph Esteybar, CT D05 - Monterey Construction Field Laboratory02/17/2023Wesley Rider
Yes
03/17/2023
2023-02-17-16-4ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJoseph Esteybar, CT D05 - Monterey Construction Field Laboratory02/17/2023Wesley Rider
Yes
03/17/2023
2023-02-17-16-5ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJoseph Esteybar, CT D05 - Monterey Construction Field Laboratory02/17/2023Joseph Esteybar
Yes
03/17/2023
2023-02-17-16-6ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJoseph Esteybar, CT D05 - Monterey Construction Field Laboratory02/17/2023Joseph Esteybar
Yes
03/17/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-02-17-16-3 ASTM C143-20 (Verified)
DIME Test ID: 2023-02-17-16-4 ASTM C1064-17 (Verified)
DIME Test ID: 2023-02-17-16-5 ASTM C143-10a (Verified)