Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2022-11-01-59

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213707
DEA: 081C38U4
EFIS: 0817000196
DIST-CO-RTE-PM08-RIV-10-6.7/R25.1
Award Date11/26/2019
Closeout Date11/01/2023
Work DescriptionRemove concrete pavement and base, and place HMA and JPCP
Location DescriptionROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
QA Service Level1 (Verified on 01/09/2020)

Sample Information

Sample Taken Date11/01/2022 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/02/2022
Sample typeAcceptance A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byMartin Marietta QC Last name of sampler or witnessed byMartin Marietta QC
Title of sampler Telephone number of sampler
Laboratory sample identification0723-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marieta-Lake Elsinor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-11-01-59-1ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)Sunday Agude, CT D08 - Fontana Southern Regional Laboratory11/03/2022Sunday Agude
Yes
11/16/2022
2022-11-01-59-2ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)Sm Ali, CT D08 - Fontana Southern Regional Laboratory11/04/2022Sm Ali
Yes
11/16/2022
2022-11-01-59-3ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)Sm Ali, CT D08 - Fontana Southern Regional Laboratory11/04/2022Sm Ali
Yes
11/16/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-11-01-59-1 ASTM D36-14ε1 (Verified)
DIME Test ID: 2022-11-01-59-2 ASTM D217-16 (Verified)
DIME Test ID: 2022-11-01-59-3 ASTM D5329-16 (Verified)