Sample Record

Owner Lab

  • CT D08 - Fontana Field Testing Laboratory

DIME Sample ID 2021-12-08-27

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213707
DEA: 081C38U4
EFIS: 0817000196
DIST-CO-RTE-PM08-RIV-10-6.7/R25.1
Award Date11/26/2019
Closeout Date11/01/2023
Work DescriptionRemove concrete pavement and base, and place HMA and JPCP
Location DescriptionROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
QA Service Level1 (Verified on 01/09/2020)

Sample Information

Sample Taken Date12/08/2021 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2021
Sample typeQuality Assurance A brief description of the sampleJPCP beams
The quantity of what the sample constitutes4 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byZ. Roush/ J. Burton Last name of sampler or witnessed byZ. Roush/ J. Burton
Title of sampler Telephone number of sampler
Laboratory sample identification28ISA1,28ISA2,28ISB1,28ISB2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCoffman Specialties, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1906-31
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-12-08-27-1CTM 523-July 2012: Method of Test for Flexural Strength of ConcreteM. Warde, K. Patel, CT D08 - Fontana Field Testing Laboratory12/11/2021Chizitere Ozuruigbo
Yes
12/15/2021
2021-12-08-27-2CTM 523-July 2012: Method of Test for Flexural Strength of ConcreteM. Warde, K. Patel, CT D08 - Fontana Field Testing Laboratory12/11/2021Chizitere Ozuruigbo
Yes
12/15/2021
2021-12-08-27-3CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteZ. Roush/ J.Burton, CT D08 - Fontana Field Testing Laboratory12/08/2021Chizitere Ozuruigbo
Yes
12/15/2021
2021-12-08-27-4CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteZ. Roush/ J. Burton, CT D08 - Fontana Field Testing Laboratory12/08/2021Chizitere Ozuruigbo
Yes
12/15/2021
2021-12-08-27-5CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodZ. Roush/ J. Burton, CT D08 - Fontana Field Testing Laboratory12/08/2021Chizitere Ozuruigbo
Yes
12/15/2021
2021-12-08-27-6CTM 523-July 2012: Method of Test for Flexural Strength of ConcreteK. Patel, A. Nguyen, CT D08 - Fontana Field Testing Laboratory01/05/2022Mohammed Haque
Yes
01/05/2022
2021-12-08-27-7CTM 523-July 2012: Method of Test for Flexural Strength of ConcreteK. Patel, A. Nguyen, CT D08 - Fontana Field Testing Laboratory01/05/2022Mohammed Haque
Yes
01/05/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-12-08-27-1 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-12-08-27-2 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-12-08-27-3 CTM 533-June 2010 (Verified)
DIME Test ID: 2021-12-08-27-4 CTM 518-June 2010 (Verified)
DIME Test ID: 2021-12-08-27-5 CTM 504-June 2010 (Verified)
DIME Test ID: 2021-12-08-27-6 CTM 523-July 2012 (Verified)
DIME Test ID: 2021-12-08-27-7 CTM 523-July 2012 (Verified)