Sample Record

Owner Lab

  • CT - Southern Regional Laboratory

DIME Sample ID 2021-06-25-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214216
DEA: 071XM404
EFIS: 0719000232
DIST-CO-RTE-PM07-VEN-33-22.16
Award DateNot set
Closeout DateNot set
Work DescriptionThis is the emergency project to repair pavement cracking, stabilize the eroded slope, construct a soldier pile tieback wall and reconstruct the steel post MGS
Location DescriptionVentura County on Route 33 at PM.22.16.
QA Service Level1 (Verified on 08/27/2019)

Sample Information

Sample Taken Date06/25/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/29/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 No LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Agg., 2 Bags Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byBrock
Title of sampler Telephone number of sampler
Laboratory sample identification0393A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0046
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number13762 A detailed description of where the material sample was collectedBelt Cut at Granite Construction Co.
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number2 JMF Verification ID

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-06-25-5-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Satish Jain/Dominic MontemayorCT - Southern Regional Laboratory07/01/2021Satish Jain
Yes
07/06/2021Combined Virgin Aggregate Gradation
2021-06-25-5-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Danilo FerrerCT - Southern Regional Laboratory07/02/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Larry DiazCT - Southern Regional Laboratory07/02/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-4AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Larry DiazCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-5AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish JainCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-6AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish JainCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-7AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Larry DiazCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish JainCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021
2021-06-25-5-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSatish JainCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021Rap Gradation After Ignition
2021-06-25-5-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSatish Jain/Dominic MontemayorCT - Southern Regional Laboratory07/03/2021Satish Jain
Yes
07/06/2021Combined RAP/Virgin Aggregate Gradation W/Correlation Factors Applied