Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2021-03-16-13

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/16/2021 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/16/2021
Sample typeAnnual Source Testing A brief description of the sampleFly Ash
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byN/A Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identificationCM215186 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertson Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandRobertsons
MillEren Energy Type of Cementitious MaterialClass F or N Flyash

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-03-16-13-2ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory05/17/2021Benjamin Lenz
Yes
06/22/20217 day test -- Specimen 3 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
2021-03-16-13-3ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory06/07/2021Benjamin Lenz
Yes
06/22/202128 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
2021-03-16-13-4ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) SieveAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory04/22/2021Benjamin Lenz
Yes
06/22/2021

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-03-16-13-2 ASTM C109-16a (Verified)
DIME Test ID: 2021-03-16-13-3 ASTM C109-16a (Verified)
DIME Test ID: 2021-03-16-13-4 ASTM C430-8 (Verified)