Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2021-04-02-8
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
Award Date | 06/06/2018 |
Closeout Date | Not set |
Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
Location Description | LA/SBD County Line to PM 13.2 near I-15 |
QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
Sample Taken Date | 04/02/2021 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2021 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Micheal | Last name of sampler or witnessed by | Hobbs |
Title of sampler | QA Inspector | Telephone number of sampler | |
Laboratory sample identification | 1015-1A | Linked DIME Sample ID | 2021-04-02-8 |
The fabricator/manufacturer/facility name | cemex | Transportation Laboratory (TL) Number | 1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Sulton Ave OC |
Material Information
Material Type | Concrete | The concrete mix design number | 1610887 |
---|---|---|---|
The truck number from where the sample was collected | 10070485 | The batch plant ticket number from where the sample was collected | 29559001 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Cemex | |
A detailed description of where the material sample was collected | Center span at bent cap,bridge deck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-04-02-8-1 ASTM C39-10 (Verified)
DIME Test ID: 2021-04-02-8-2 ASTM C39-10 (Verified)