Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2021-04-02-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214355
DEA: 120K0214
EFIS: 1214000096
DIST-CO-RTE-PM12-ORA-5-12.4/14.5
Award Date12/20/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
QA Service Level1 (Verified on 10/31/2019)

Sample Information

Sample Taken Date04/02/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/05/2021
Sample typeQuality Assurance A brief description of the sampleASTM A706 GR 60 Welded Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of sampler Telephone number of sampler7073428602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-039-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)157720
Hoop Manufacturer Lot Number(s)Lot 4 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop3'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-04-02-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking
2021-04-02-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking
2021-04-02-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-04-02-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-04-02-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-04-02-4-3 CTM 670-December 2013 (Verified)