Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-07-15-5

Project Information

Project IdentifiersProject ID: 214601
DEA: 041J5694
EFIS: 0419000313
DIST-CO-RTE-PM04-SM-101-0.0/21.8
Award Date12/03/2019
Closeout Date09/28/2022
Work DescriptionSan Mateo US 101 Express Lanes North
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date07/15/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/15/2020
Sample typeQuality Assurance A brief description of the sampleASTM A325 1-1/4"x 3-3/4" Bolt
The quantity of what the sample constitutes25 pcs From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byKopenski
Title of samplerQA Telephone number of sampler(310) 745-9655
Laboratory sample identificationL149-073-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)060920CR
Heat Number(s)Bolt 100893998, Nut DL17100198 Nut Mfg. Lot Number(s)388517A
Washer Mfg. Lot Number(s) Bolt SpecificationASTM A325
Bolt Length(s)3-3/4" Nut SpecificationASTM A563
Washer Specificationn/a FinishMech.Zinc Galv. ASTM B695
Diameter/Size1-1/4"x 3-3/4" Bolt Mfg. Lot Number416756A
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-07-15-5-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020fsaylor
Yes
08/19/2020A325 Bolt
2020-07-15-5-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020fsaylor
Yes
08/19/2020Proff Load
2020-07-15-5-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020fsaylor
Yes
08/19/2020Proff Load
2020-07-15-5-4ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020Fred Saylor
Yes
08/19/2020
2020-07-15-5-5ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020Fred Saylor
Yes
08/19/2020
2020-07-15-5-6ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020Fred Saylor
Yes
08/19/2020
2020-07-15-5-7ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/18/2020Fred Saylor
Yes
08/19/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-07-15-5-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-07-15-5-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-07-15-5-3 ASTM F606-14a (Verified)
DIME Test ID: 2020-07-15-5-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-15-5-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-15-5-6 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-15-5-7 ASTM B499-14 (Verified)