Sample Record
Owner Lab
- CT HQ - Sacramento Hot Mix Asphalt Laboratory
DIME Sample ID 2019-11-15-7
Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/15/2019 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2019 |
Sample type | Quality Control | A brief description of the sample | Combined 1/2" Type A (Virgin Aggregate) |
The quantity of what the sample constitutes | JMF Submittal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Sampler First Name | Last name of sampler or witnessed by | Sampler Last Name |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010::CALMAT/PLEASANTON |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Untreated Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
JMF Information
HMA Design ID | JMF3512-2019-144-320819_TEST_11/2019 | Date Created | 11/08/2019 |
---|---|---|---|
Submittal | JMF3511-208-2019-120 Submittal Accepted for Verification| JMF3513-2020-119 JMF3511-208-2019-121 Submittal In Progress| JMF3513-2020-120 JMF3511-208-2019-122 Submittal Authorized For Use| JMF3513-2020-121 JMF3511-208-2021-7 Submittal Completeness in Review| JMF3513-2021-73 |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-11-15-7-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-11-15-7-2 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-11-15-7-3 AASHTO T176-08 (Verified)
DIME Test ID: 2019-11-15-7-4 AASHTO T304-11 (Verified)
DIME Test ID: 2019-11-15-7-5 ASTM D4791-10 (Verified)
DIME Test ID: 2019-11-15-7-6 CTM 204-June 2010 (Verified)
DIME Test ID: 2019-11-15-7-7 AASHTO T85-13 (Verified)
DIME Test ID: 2019-11-15-7-8 AASHTO T84-14 (Verified)
DIME Test ID: 2019-11-15-7-9 CTM 227-December 2014 (Verified)
DIME Test ID: 2019-11-15-7-10 AASHTO T210-15 (Verified)