Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2019-10-17-1

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/17/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/18/2019
Sample typeQuality Assurance A brief description of the sample7/8" X 36" A449 HEAVY HECX BOLTS
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byPaul Last name of sampler or witnessed byFarinha
Title of samplerASSOC STEEL INSP Telephone number of sampler9167987102
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS51-045-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3087319 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA449
Bolt Length(s)36" Nut SpecificationN/A
Washer SpecificationN/A FinishGalvanized
Diameter/Size7/8" Bolt Mfg. Lot Number56635-1
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-10-17-1-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019bewing
Yes
10/29/2019A449 Bolt
2019-10-17-1-2ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019
2019-10-17-1-3ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019
2019-10-17-1-4ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019
2019-10-17-1-5ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019
2019-10-17-1-6ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019
2019-10-17-1-7ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Brian Ewing
Yes
10/29/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-10-17-1-1 ASTM F606-14 (Verified)
DIME Test ID: 2019-10-17-1-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-5 ASTM B499-14 (Verified)
DIME Test ID: 2019-10-17-1-6 ASTM B499-14 (Verified)
DIME Test ID: 2019-10-17-1-7 ASTM B499-14 (Verified)