Sample Record
Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2019-10-17-1
Sample is locked from editing. info
Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/17/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/18/2019 |
Sample type | Quality Assurance | A brief description of the sample | 7/8" X 36" A449 HEAVY HECX BOLTS |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Farinha |
Title of sampler | ASSOC STEEL INSP | Telephone number of sampler | 9167987102 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S51-045-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3087319 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A449 | |
Bolt Length(s) | 36" | Nut Specification | N/A |
Washer Specification | N/A | Finish | Galvanized |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 56635-1 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-10-17-1-1 ASTM F606-14 (Verified)
DIME Test ID: 2019-10-17-1-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-17-1-5 ASTM B499-14 (Verified)
DIME Test ID: 2019-10-17-1-6 ASTM B499-14 (Verified)
DIME Test ID: 2019-10-17-1-7 ASTM B499-14 (Verified)