Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2019-07-17-1

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/17/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2019
Sample typeQuality Assurance A brief description of the sampleASTM F1554 Gr 55 Anchor Bolt with nut and washer
The quantity of what the sample constitutes237 + 3 Samples From where was the sample collectedManufacturer
First name of sampler or witnessed bySteven Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler646-632-7821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAM Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554 Gr 55
Bolt Length(s)Unknown Nut SpecificationA194 Gr 2H
Washer SpecificationF436 Finish
Diameter/SizeUnknown Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-07-17-1-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian
Yes
07/31/2019Nut Proof Load
2019-07-17-1-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian
Yes
07/31/2019Nut Proof Load
2019-07-17-1-3ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian
Yes
07/31/2019
2019-07-17-1-4ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian
Yes
07/31/2019
2019-07-17-1-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019
2019-07-17-1-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019
2019-07-17-1-7ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019
2019-07-17-1-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019
2019-07-17-1-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019
2019-07-17-1-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2019Brian Ewing
Yes
07/31/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-07-17-1-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-07-17-1-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-07-17-1-3 ASTM A370-15 (Verified)
DIME Test ID: 2019-07-17-1-4 ASTM A370-15 (Verified)
DIME Test ID: 2019-07-17-1-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-17-1-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-16 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-17 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-18 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-19 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-20 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-21 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-22 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-23 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-24 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-25 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-17-1-26 ASTM E18-15 (Verified)
DIME Test ID: 2019-07-17-1-27 ASTM E18-15 (Verified)
DIME Test ID: 2019-07-17-1-28 ASTM E18-15 (Verified)