Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2019-06-18-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date06/18/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2019
Sample typeVerification A brief description of the sample3/4 HMA-A R10
The quantity of what the sample constitutesPSE 12 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Sun Valley Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0364A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Vulcan Sun Valley
The fabricator's/manufacturer's product name for the sample3/4 HMA-A R10 The fabricator/manufacturer designation for the sample220805 SVA VLO
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
No assigned tests for this sample.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-06-18-5-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/24/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-2CTM 205-December 2010: Method of Test for Determining Percentage of Crushed ParticlesSatish Jain, CT D08 - Fontana Southern Regional Laboratory06/26/2019Michael Magana
Yes
07/03/2019One face reported
2019-06-18-5-3CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse AggregateDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/24/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-4CTM 207-March 2012: Method of Test for Specific Gravity and Absorption of Fine AggregateDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/24/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-5CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing MachineDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/24/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-6CTM 217-June 2011: Method of Test for Sand EquivalentDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/24/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-7ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory06/26/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-8CTM 234-August 2010: Method of Test for Uncompacted Void Content of Fine AggregatesSatish Jain, CT D08 - Fontana Southern Regional Laboratory06/26/2019Michael Magana
Yes
07/03/2019
2019-06-18-5-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/25/2019Michael Magana
Yes
07/03/2019RAP Gradation After Ignition Oven
2019-06-18-5-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDanilo Ferrer, CT D08 - Fontana Southern Regional Laboratory06/25/2019Michael Magana
Yes
07/03/2019Combined Virgin Aggregate/RAP Gradation w/Correlation Factors Applied

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-06-18-5-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2019-06-18-5-2 CTM 205-December 2010 (Verified)
DIME Test ID: 2019-06-18-5-3 CTM 206-October 2011 (Verified)
DIME Test ID: 2019-06-18-5-4 CTM 207-March 2012 (Verified)
DIME Test ID: 2019-06-18-5-5 CTM 211-May 2010 (Verified)
DIME Test ID: 2019-06-18-5-6 CTM 217-June 2011 (Verified)
DIME Test ID: 2019-06-18-5-7 ASTM D4791-10 (Verified)
DIME Test ID: 2019-06-18-5-8 CTM 234-August 2010 (Verified)
DIME Test ID: 2019-06-18-5-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2019-06-18-5-10 CTM 202-November 2011 (Verified)