Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2019-03-04-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213470 DEA: 06394604 EFIS: 0600020595 |
DIST-CO-RTE-PM | 06-FRE-269-10.6/12.4 |
Award Date | 11/02/2018 |
Closeout Date | 10/15/2020 |
Work Description | REPLACE BRIDGES AND RECONSTRUCT ROADWAY. |
Location Description | FRESNO COUNTY NEAR HURON FROM 1.0 MILE NORTH OF PALMER AVENUE TO 0.4 MILE SOUTH OF ROUTE 198 |
QA Service Level | 1 (Verified on 09/25/2018) |
Sample Information
Sample Taken Date | 03/04/2019 |
Sample Unique Key | 1 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 03/06/2019 |
Sample type | Quality Assurance |
A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 16 |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Osiel |
Last name of sampler or witnessed by | Ramirez Alvarez |
Title of sampler | CT METS QA INSPECTOR |
Telephone number of sampler | 5599740870 |
Laboratory sample identification | |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | TNT Rebar |
Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123 |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | SMTL TM5 - Welded Hoops |
Production or Authorization Testing | Authorization Testing |
Service or Ultimate | Ultimate |
Rebar Heat Number(s) | 4082019 |
Hoop Manufacturer Lot Number(s) | 33, 37, 42, 47, |
Material Standard Code | ASTM A706 |
Material Grade | 60 |
Rebar Size | 5 |
Diameter of Hoop | 1'-4" |
Epoxy Coated | No |
Epoxy Coating Color | NA |
Rebar Manufacturer | TNT Rebar |
Welding Company | TNT Rebar Company |
Coating Standards | Uncoated |
Weld Type | Flash Welded |
---|
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2019-03-04-1-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke in Heat Affected Zone; OK Necking | |
2019-03-04-1-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-9 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke; OK Necking | |
2019-03-04-1-10 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 03/08/2019 | Fred | Yes | 03/15/2019 | Bar Broke in Heat Affected Zone; OK Necking | |
56745567465674756748567495675056751567525675356754