Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2019-01-16-1
Sample is locked from editing. info
Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/16/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/25/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
The quantity of what the sample constitutes | 197 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
Title of sampler | QA Inspector | Telephone number of sampler | 5103253065 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AandM Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-061-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3076371, 75070666, 278504 | Nut Mfg. Lot Number(s) | 28623-75070666 |
Washer Mfg. Lot Number(s) | 309577 | Bolt Specification | F1554 |
Bolt Length(s) | 12" | Nut Specification | A194 |
Washer Specification | F436 | Finish | GAL |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 3076371 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-01-16-1-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-01-16-1-3 ASTM F606-14a (Verified)
DIME Test ID: 2019-01-16-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-16-1-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-16 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-17 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-18 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-19 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-20 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-21 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-22 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-23 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-24 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-16-1-25 ASTM E18-15 (Verified)
DIME Test ID: 2019-01-16-1-26 ASTM E18-15 (Verified)
DIME Test ID: 2019-01-16-1-27 ASTM E18-15 (Verified)
DIME Test ID: 2019-01-16-1-28 ASTM F606-14 (Verified)