Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2019-01-14-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/14/2019 |
Sample Unique Key | 1 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 01/14/2019 |
Sample type | Annual Source Testing |
A brief description of the sample | Type I/II |
The quantity of what the sample constitutes | 1 Bucket |
From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown |
Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown |
Telephone number of sampler | Unknown |
Laboratory sample identification | CM195902 |
Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | LaFarge |
Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | Cementitious |
Brand | LaFarge |
Mill | Richmond BC |
Type of Cementitious Material | Type II Cement |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2019-01-14-1-2 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams | CT HQ - Sacramento Cement Testing Laboratory | 04/11/2019 | Spencer Adams | Yes | 01/08/2021 | 3 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109 | |
2019-01-14-1-3 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams | CT HQ - Sacramento Cement Testing Laboratory | 04/15/2019 | Spencer Adams | Yes | 01/08/2021 | 7 day test | |
2019-01-14-1-4 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams | CT HQ - Sacramento Cement Testing Laboratory | 05/06/2019 | Spencer Adams | Yes | 01/08/2021 | 28 day test | |
2019-01-14-1-5 | ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar | Stephen Donnelly | CT HQ - Sacramento Cement Testing Laboratory | 04/23/2019 | Stephen Donnelly | Yes | 01/08/2021 | | |
2019-01-14-1-6 | ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle | Stephen Donnelly | CT HQ - Sacramento Cement Testing Laboratory | 06/10/2019 | Stephen Donnelly | Yes | 01/08/2021 | | |
2019-01-14-1-7 | ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus | Stephen Donnelly | CT HQ - Sacramento Cement Testing Laboratory | 04/17/2019 | Stephen Donnelly | Yes | 01/08/2021 | | |
829568295784034585166156758361