Sample Record

Owner Lab

  • CT QASI - Bay Area Field Laboratory

DIME Sample ID 2018-12-14-3

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/14/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/18/2018
Sample typeVerification A brief description of the sampleA449 HDG bolt, A325 MG bolts, A563-DH MG nuts, F436 MG washers
The quantity of what the sample constitutes5 and 12 ea From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCA METS QA Inspector Telephone number of sampler801-669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-251-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)188551,10431710,10176580,20391740,100794431,7506122, 10466960,511580, 31542750, 6214577204, 0159721, 4180620, 177468 Nut Mfg. Lot Number(s)decker 17-04-005, Unytite 28028-6214577204, 26473-177468
Washer Mfg. Lot Number(s)preD1214,D2166,D3945,D6010 Bolt SpecificationA325 MG
Bolt Length(s)17 1/2", 2 1/2", 2 3/4", 2 1/4", 5" Nut SpecificationA563-DH MG
Washer SpecificationF436 MG FinishMG and HDG
Diameter/Size7/8"x17 1/2", 1/2"x2 1/2", 1/2"x2 3/4", 1"x2 Bolt Mfg. Lot NumberSLSB, Unytite, M4778,M4163,BM0196BM0655,M4451
Rocap Test Requirement(s)none Lubricant Requirements(s)none

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-12-14-3-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019Head Popped Off
2018-12-14-3-2ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A449 Bolt 10 Degree Wedge
2018-12-14-3-3ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A449 Bolt 10 Degree Wedge
2018-12-14-3-4ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019Head Popped Off
2018-12-14-3-5ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A449 Bolt 10 Degree Wedge
2018-12-14-3-6ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A325
2018-12-14-3-7ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A325
2018-12-14-3-8ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A325
2018-12-14-3-9ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A325
2018-12-14-3-10ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)BrianCT HQ - Sacramento Structural Materials Testing Laboratory12/20/2018Brian
Yes
01/07/2019A325