Sample Record
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2018-12-07-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/07/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/07/2018 |
Sample type | Annual Source Testing | A brief description of the sample | Type II/V |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM185850 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Lehigh Redding | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | Lehigh |
---|---|---|---|
Mill | Redding | Type of Cementitious Material | Type II/V Cement |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2018-12-07-2-2 | ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens) | SA, CT HQ - Sacramento Cement Testing Laboratory | 01/25/2019 | No | 3 Day Break - superseded | Info | ||
2018-12-07-2-4 | ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens) | SA, CT HQ - Sacramento Cement Testing Laboratory | 02/19/2019 | No | 28 Day Break - failed for inconsistency - superseded | Info | ||
2018-12-07-2-5 | ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 01/04/2019 | Stephen Donnelly | Yes | 01/07/2021 | ||
2018-12-07-2-6 | ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 01/24/2019 | Stephen Donnelly | Yes | 01/07/2021 | ||
2018-12-07-2-7 | ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 04/17/2019 | Stephen Donnelly | Yes | 01/07/2021 | ||
2018-12-07-2-8 | ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens) | SA, CT HQ - Sacramento Cement Testing Laboratory | 01/29/2019 | No | 7 Day Break - superseded | Info | ||
2018-12-07-2-9 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 03/29/2019 | Spencer Adams | Yes | 01/07/2021 | 3 day test -- Specimen 3 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109 | |
2018-12-07-2-10 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 04/02/2019 | Spencer Adams | Yes | 01/07/2021 | 7 day test | |
2018-12-07-2-11 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 04/23/2019 | Spencer Adams | Yes | 01/07/2021 | 28 day test -- Specimen 3 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109 |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2018-12-07-2-2 ASTM C109-11
DIME Test ID: 2018-12-07-2-4 ASTM C109-11
DIME Test ID: 2018-12-07-2-5 ASTM C185-15a (Verified)
DIME Test ID: 2018-12-07-2-6 ASTM C191-13 (Verified)
DIME Test ID: 2018-12-07-2-7 ASTM C204-11 (Verified)
DIME Test ID: 2018-12-07-2-8 ASTM C109-11
DIME Test ID: 2018-12-07-2-9 ASTM C109-16a (Verified)
DIME Test ID: 2018-12-07-2-10 ASTM C109-16a (Verified)
DIME Test ID: 2018-12-07-2-11 ASTM C109-16a (Verified)