Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2018-07-18-4

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/18/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2018
Sample typeQuality Assurance A brief description of the sampleF1554 Grade 55 HDG Anchor Bolts
The quantity of what the sample constitutes149 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerQAI Telephone number of sampler5106933545
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameAandM Nut and Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL02-038-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)3078714 Nut Mfg. Lot Number(s)28220
Washer Mfg. Lot Number(s)307794 Bolt Specification1554
Bolt Length(s)30" Nut SpecificationA194
Washer SpecificationF436 FinishHot dip galvanized
Diameter/Size1" Bolt Mfg. Lot Number42964-PPO
Rocap Test Requirement(s) Lubricant Requirements(s)YES

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-07-18-4-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian
Yes
08/13/2018Nut Proof
2018-07-18-4-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian
Yes
08/13/2018Nut Proof
2018-07-18-4-3ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Fred
Yes
08/13/2018
2018-07-18-4-4ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Fred
Yes
08/13/2018
2018-07-18-4-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018
2018-07-18-4-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018
2018-07-18-4-7ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018
2018-07-18-4-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018
2018-07-18-4-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018
2018-07-18-4-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/27/2018Brian Ewing
Yes
08/13/2018

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-07-18-4-1 ASTM F606-14a (Verified)
DIME Test ID: 2018-07-18-4-2 ASTM F606-14a (Verified)
DIME Test ID: 2018-07-18-4-3 ASTM A370-15 (Verified)
DIME Test ID: 2018-07-18-4-4 ASTM A370-15 (Verified)
DIME Test ID: 2018-07-18-4-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-07-18-4-13 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-14 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-15 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-16 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-17 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-18 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-19 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-20 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-21 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-22 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-23 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-24 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-25 ASTM B499-14 (Verified)
DIME Test ID: 2018-07-18-4-26 ASTM E18-15 (Verified)
DIME Test ID: 2018-07-18-4-27 ASTM E18-15 (Verified)
DIME Test ID: 2018-07-18-4-28 ASTM E18-15 (Verified)