Owner Lab
- CT QASI - Bay Area Field Laboratory
DIME Sample ID 2018-06-07-1
Sample is locked from editing. info
Project Information
Project Identifiers | DEA: No Project |
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/07/2018 |
Sample Unique Key | 1 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 06/08/2018 |
Sample type | Verification |
A brief description of the sample | 7/8 in x 20 in. A449 HDG bolt |
The quantity of what the sample constitutes | 3 |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David |
Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector |
Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown |
Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS |
Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-120-18 |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | SMTL TM3 - Fastener Assembly |
Rocap Number(s) | n/a |
Heat Number(s) | 75065948 |
Nut Mfg. Lot Number(s) | none |
Washer Mfg. Lot Number(s) | n/a |
Bolt Specification | A449 |
Bolt Length(s) | 20" |
Nut Specification | n/a |
Washer Specification | n/a |
Finish | HDG |
Diameter/Size | 7/8" x 20" |
Bolt Mfg. Lot Number | 29970 |
Rocap Test Requirement(s) | none |
Lubricant Requirements(s) | none |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2018-06-07-1-1 | ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred | Yes | 06/18/2018 | A449 | |
2018-06-07-1-2 | ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
2018-06-07-1-3 | ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
2018-06-07-1-4 | ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
2018-06-07-1-5 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
2018-06-07-1-6 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
2018-06-07-1-7 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/11/2018 | Fred Saylor | Yes | 06/18/2018 | | |
45602456034560445605456064560745608