Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2021-03-05-7
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101,135-70.6/71.2;0.1 |
| Award Date | 11/17/2020 |
| Closeout Date | 01/11/2024 |
| Work Description | CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA. |
| Location Description | SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION |
| QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
| Sample Taken Date | 03/05/2021 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/16/2021 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Hoops |
| The quantity of what the sample constitutes | 150 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
| Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-069-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202028162 |
| Hoop Manufacturer Lot Number(s) | 4 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 2'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-03-05-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-05-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-05-7-3 CTM 670-December 2013 (Verified)