Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-03-05-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214993
DEA: 051F5004
EFIS: 0514000003
DIST-CO-RTE-PM05-SB-101,135-70.6/71.2;0.1
Award Date11/17/2020
Closeout Date01/11/2024
Work DescriptionCONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA.
Location DescriptionSANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date03/05/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/16/2021
Sample typeQuality Assurance A brief description of the sample Flash Welded Hoops
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-069-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202028162
Hoop Manufacturer Lot Number(s)4 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-03-05-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/2021fsaylor
Yes
03/16/2021OK Necking
2021-03-05-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/2021fsaylor
Yes
03/16/2021OK Necking
2021-03-05-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/16/2021fsaylor
Yes
03/16/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-03-05-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-03-05-7-2 CTM 670-December 2013 (Verified)