Summary for Test 2020-10-09-5-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date10/09/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2020
Sample typeVerification A brief description of the sampleASTM F3125 Grade A325 5/8-11 x 2 3/4 bolt
The quantity of what the sample constitutes30 From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byWebster
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Bolt Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB201-023-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L1414071
Heat Number(s)10576920 62151690 B51833 Nut Mfg. Lot Number(s)32394-6215169002
Washer Mfg. Lot Number(s)0219-089 Bolt SpecificationASTM F3125 Grade A325
Bolt Length(s)2 3/4" Nut SpecificationASTM A563 DH
Washer SpecificationASTM F436 FinishASTM A153 Hot Dip
Diameter/Size5/8"-11 Bolt Mfg. Lot Number820273
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-10-09-5
DIME Test ID: 2020-10-09-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-10-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/22/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A32394-621516900236192Proof Loadfsaylor

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/27/2020