Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-10-09-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date10/09/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2020
Sample typeVerification A brief description of the sampleASTM F3125 Grade A325 5/8-11 x 2 3/4 bolt
The quantity of what the sample constitutes30 From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byWebster
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Bolt Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB201-023-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L1414071
Heat Number(s)10576920 62151690 B51833 Nut Mfg. Lot Number(s)32394-6215169002
Washer Mfg. Lot Number(s)0219-089 Bolt SpecificationASTM F3125 Grade A325
Bolt Length(s)2 3/4" Nut SpecificationASTM A563 DH
Washer SpecificationASTM F436 FinishASTM A153 Hot Dip
Diameter/Size5/8"-11 Bolt Mfg. Lot Number820273
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-10-09-5-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020fsaylor
Yes
10/27/2020A325
2020-10-09-5-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020fsaylor
Yes
10/27/2020Proof Load
2020-10-09-5-3ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020
2020-10-09-5-4ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020
2020-10-09-5-5ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020
2020-10-09-5-6ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020
2020-10-09-5-7ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020
2020-10-09-5-8ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/22/2020Brian Ewing
Yes
10/27/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-10-09-5-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-09-5-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-10-09-5-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-09-5-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-10-09-5-5 ASTM B499-14 (Verified)
DIME Test ID: 2020-10-09-5-6 ASTM B499-14 (Verified)
DIME Test ID: 2020-10-09-5-7 ASTM B499-14 (Verified)
DIME Test ID: 2020-10-09-5-8 ASTM E18-15 (Verified)