Summary for Test 2020-10-05-5-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
Award Date | 06/06/2018 |
Closeout Date | Not set |
Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
Location Description | LA/SBD County Line to PM 13.2 near I-15 |
QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
Sample Taken Date | 10/05/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/09/2020 |
Sample type | Preliminary | A brief description of the sample | #5 Black Steel with Coupler |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Emanuel | Last name of sampler or witnessed by | Santamaria |
Title of sampler | Materials Control Coordinator | Telephone number of sampler | (909) 557-3818 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bar Splice Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Sultana |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | Bar Splice Products | Intermediate Assembler or Fabricator | CMC Rebar |
Rebar Size | #5 | Coupler Model | Zaplock 05DBZA |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | Heat number 8163 Production Run S3814R7-5DBZ | Rebar Heat Number(s) | 4100995 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2020-10-05-5
DIME Test ID: 2020-10-05-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-10-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/20/2020
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | 5/16mm | 0.31 | 31093.56 | 100302 | Service splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service splice
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/20/2020 ✔