Summary for Test 2020-10-08-3-6
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/08/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/12/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A563-DH |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213-435-4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-257-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 33262-201117 | |
Washer Mfg. Lot Number(s) | Bolt Specification | n/a | |
Bolt Length(s) | Nut Specification | ASTM A563-DH | |
Washer Specification | n/a | Finish | Hot Dipped Galv. |
Diameter/Size | 3/4"-10 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-10-08-3
DIME Test ID: 2020-10-08-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2020-10-19
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 10/14/2020
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 33262-201117
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: U DH
Size: .75 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2020 ✔