Summary for Test 2020-09-23-10-4

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214228
DEA: 120N4904
EFIS: 1214000050
DIST-CO-RTE-PM12-ORA-91-R12.5/R13.9
Award Date11/29/2022
Closeout Date11/07/2023
Work DescriptionVEHICLE ENFORCEMENT FACILITY IMPROVEMENT AT PERALTA WEIGH STATION.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 1.0 MILE EAST OF ROUTE 91/90 SEPARATION TO 0.5 MILE WEST OF WEIR CANYON ROAD UNDERCROSSING
QA Service Level1 (Verified on 08/13/2019)

Sample Information

Sample Taken Date09/23/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/28/2020
Sample typeQuality Assurance A brief description of the sample1/2" x 1 3/4" HDG bolts
The quantity of what the sample constitutes90 From where was the sample collectedDistributor
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBristol Machine Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-215-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)NF11203296 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationASTM A325
Bolt Length(s)1 3/4" Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size1/2" Bolt Mfg. Lot Number296338A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-09-23-10
DIME Test ID: 2020-09-23-10-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-09-30

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 09/29/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 296338A
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 N
Size: .5 in
Bolt Length: 1.75 in
Measurement Average: 4.61 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/30/2020