Summary for Test 2020-07-16-37-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
Award Date | 12/03/2019 |
Closeout Date | 09/28/2022 |
Work Description | San Mateo US 101 Express Lanes North |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 07/16/2020 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2020 |
Sample type | Quality Control | A brief description of the sample | PCC Core |
The quantity of what the sample constitutes | 33 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Peter | Last name of sampler or witnessed by | Manchester |
Title of sampler | Field Technician | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Central Concrete Supply | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | CIDH G-17 STA 633-47 |
Material Information
Material Type | Concrete | The concrete mix design number | DDLSP8Q3 |
---|---|---|---|
The truck number from where the sample was collected | 1658 | The batch plant ticket number from where the sample was collected | 18067467 |
Concrete batch plant | Central Concrete Supply San Jose Plant | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CIDH G-17 | Where the material sample would have been placed if not sampled | SIGN CIDH |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2020-07-16-37
DIME Test ID: 2020-07-16-37-1
Testing Lab: Kiewit Infrastructure West Company - Redwood City
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-08-17
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Matthew Liu
Date of test: 08/13/2020
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617/CTM521
Maximum load on cylinder 1: 193290 lb
Maximum load on cylinder 2: 190710 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6790 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2020 ✔