Summary for Test 2015-01-06-4-4

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date01/06/2015 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2015
Sample typeAcceptance A brief description of the sampleMSC Backfill Materials 2
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byHarold Last name of sampler or witnessed byFrench
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification5008B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSanta Clarita Stockpile Transportation Laboratory (TL) NumberC686459
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedToe of Santa Clarita stockpile
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2015-01-06-4
DIME Test ID: 2015-01-06-4-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-23

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 01/14/2015
Soil sample resistance (lab measure 1): 3700 Ohms
Soil sample resistance (lab measure 2): 2850 Ohms
Soil sample resistance (lab measure 3): 2800 Ohms
Soil sample resistance (lab measure 4): 2800 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 2800 Ohms
Soil sample temperature: 19.5 C
Soil box constant: 1
pH of soil: 9.25
Minimum soil resistance corrected to 15.5: 3080 Ohms
Minimum soil resistivity at 15.5: 3080 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015