Summary for Test 2018-12-06-7-2
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/06/2018 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/06/2018 |
Sample type | Annual Source Testing | A brief description of the sample | Gallup Fly Ash |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM195911 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SRMG | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | Salt River Materials Group |
---|---|---|---|
Mill | Gallup | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2018-12-06-7
DIME Test ID: 2018-12-06-7-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-01-08
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 03/25/2019
Age of specimen: 7 days
The amount of flow : 129 %
The amount of water used : 50.6 %
Compressive strength of 1st specimen : 3763 psi
Compressive strength of 2nd specimen: 3298 psi
Compressive strength of 3rd specimen : 3757 psi
Average Compressive strength (to nearest 10 psi): 3760 psi
Average Compressive strength (to nearest 10 psi) control group: 4150 psi
Strength Activity Index of Portland Cement per ASTM C109: 91 %
General comments (publicly viewable) (Max 1000 characters): 7 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
Test was verified on 1/8/2021 ✔