Summary for Test 2020-03-31-2-1
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
Award Date | 11/26/2019 |
Closeout Date | 11/01/2023 |
Work Description | Remove concrete pavement and base, and place HMA and JPCP |
Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
Sample Taken Date | 03/31/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2020 |
Sample type | Quality Assurance | A brief description of the sample | HMA-A 3/4" PG 58-34M |
The quantity of what the sample constitutes | 2 box, 8 cores | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Coffman Specialties | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 1A13, 1B13, 1C13, 1A14, 1B14, 1C14, 1A15, 1B15 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCA-Coachella | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-31-2
DIME Test ID: 2020-03-31-2-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2020-04-09
Test Results
Number of tests: 3
What test procedure is performed?: Method B
Input Type: Calculated
Tester's full name: M. Warde / S. Mirgati
Date of test: 04/08/2020
Bulk Specific Gravity: 2.352
Bulk Specific Gravity 2: 2.374
Bulk Specific Gravity 3: 2.365
Average Bulk Specific Gravity: 2.364
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2020 ✔