Summary for Test 2020-04-01-4-5
Test performed: AASHTO T96-02r10Project Information
Project Identifiers | Project ID: 213808 DEA: 080N6704 EFIS: 0800000536 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-28.1/37.4 |
Award Date | 03/12/2019 |
Closeout Date | 04/28/2022 |
Work Description | CONSTRUCT RAISED MEDIAN AND LEFT TURN LANES. |
Location Description | RIVERSIDE COUNTY NEAR HEMET FROM 0.6 MILE EAST OF ROUTE 215 TO 0.4 MILE WEST OF ACACIA AVENUE. |
QA Service Level | 1 (Verified on 12/04/2019) |
Sample Information
Sample Taken Date | 04/01/2020 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2020 |
Sample type | Verification | A brief description of the sample | 3/4 RHMA-G-SP |
The quantity of what the sample constitutes | PSUE 3 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Vulcan Corona | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0182G-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Complany - Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0027::CORONA QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 RHMA-G-SP | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | 226108 CORD SJR | A detailed description of where the material sample was collected | Belt Cut at Vulcan Corona Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-04-01-4
DIME Test ID: 2020-04-01-4-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-05-07
Test Results
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 04/08/2020
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4799 grams
Mass of sample on No.12 sieve (after 500 revolutions): 4070 grams
Percent loss after 100 revolutions: 4 %
Percent loss after 500 revolutions: 19 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2020 ✔