Summary for Test 2020-02-12-3-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213763
DEA: 060Q19A4
EFIS: 0613000152
DIST-CO-RTE-PM06-KER-58-R99.0/R100.3
Award Date02/04/2019
Closeout Date10/22/2021
Work DescriptionWIDEN SHOULDERS AND REPLACE BRIDGES
Location DescriptionKERN COUNTY NEAR TEHACHAPI FROM 0.5 MILE WEST TO 0.8 MILE EAST OF SAND CANYON UNDERCROSSING
QA Service Level1 (Verified on 01/09/2019)

Sample Information

Sample Taken Date02/12/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/13/2020
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R15
The quantity of what the sample constitutesPSUE 11 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byFernando Last name of sampler or witnessed byNajera
Title of sampler Telephone number of sampler
Laboratory sample identification0134A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Arvin Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0007, 91-15-0024
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample1412
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Granite Arvin Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-02-12-3
DIME Test ID: 2020-02-12-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-03-17

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Edmond Jabbour, Satish Jain
Date of test: 02/14/2020
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 78 %
Cumulative percent passing the 3/8 in. sieve: 58 %
Cumulative percent passing the #4 sieve: 39 %
Cumulative percent passing the #8 sieve: 28 %
Cumulative percent passing the #16 sieve: 20 %
Cumulative percent passing the #30 sieve: 14 %
Cumulative percent passing the #50 sieve: 9 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 3 %
General comments (publicly viewable) (Max 1000 characters): Lime Treated Aggregate Gradation

Test was verified on 3/17/2020