Summary for Test 2019-12-13-1-7
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 213808 DEA: 080N6704 EFIS: 0800000536 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-28.1/37.4 |
Award Date | 03/12/2019 |
Closeout Date | 04/28/2022 |
Work Description | CONSTRUCT RAISED MEDIAN AND LEFT TURN LANES. |
Location Description | RIVERSIDE COUNTY NEAR HEMET FROM 0.6 MILE EAST OF ROUTE 215 TO 0.4 MILE WEST OF ACACIA AVENUE. |
QA Service Level | 1 (Verified on 12/04/2019) |
Sample Information
Sample Taken Date | 12/13/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/16/2019 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A-SP R12 |
The quantity of what the sample constitutes | PSUE 9 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Oluoha |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 720A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Matich-Cabazon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0008::CABAZON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R12 | The fabricator/manufacturer designation for the sample | CHP-62D |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at Matich Cabazon Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-12-13-1
DIME Test ID: 2019-12-13-1-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-03-17
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 12/18/2019
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/17/2020 ✔